|Table of Contents|

Wire breakage monitoring method for cable-stayed bridge cable using magnetic gradient tensor(PDF)

长安大学学报(自然科学版)[ISSN:1006-6977/CN:61-1281/TN]

Issue:
2022年4期
Page:
52-62
Research Field:
桥梁与隧道工程
Publishing date:

Info

Title:
Wire breakage monitoring method for cable-stayed bridge cable using magnetic gradient tensor
Author(s):
JIANG Sheng-hua1 SUN Wei-he1 WANG Hao1 LIU Xiao-chun2
(1. College of Engineering and Technology, Southwest University, Chongqing 400715, China; 2. School of Civil Engineering, Central South University, Changsha 410075, Hunan, China)
Keywords:
bridge engineering cable-stayed bridge wire breakage monitoring magnetic gradient tensor location of wire breakage number of broken wires
PACS:
U448.27
DOI:
10.19721/j.cnki.1671-8879.2022.04.006
Abstract:
In order to study the monitoring method of location and number of cable wire breakage for cable-stayed bridge and eliminate the interference of environmental magnetic field, the monitoring method of wire breakage based on magnetic gradient tensor was proposed. The monitoring device for wire breakage was developed, including magnetic field sensing system and motion control system. The motion control device was assembled with non-magnetic materials such as aluminum alloy and copper connector, so as to eliminate magnetic interference in the experimental device to a great extent. The magnetic field intensity, magnetic gradient and partial modulus were analyzed for a single cable wire and a bundle of cable wire before and after wire breakage. The relationship between the magnetic gradient, partial modulus and the number of broken wires was studied. The results show that the ratio of environmental magnetic field intensity to single cable wire's magnetic field intensity is 98.47% to 157.76%, so the influence of environmental magnetic field intensity cannot be ignored. The ratio of environmental magnetic gradient(partial modulus)to single cable wire's is 3.34% to 6.67%, so it can be ignored. The environmental magnetic gradient and partial modulus are far less than those of the cable wire. When a single wire and a whole bundle of cable wire are broken, the magnetic gradient and partial modulus curves change suddenly at the broken region, including crest or trough, etc. The number of broken wires in the whole bundle of cables is related to the magnetic characteristic parameters such as the depth and width of curve crest(or trough)and the area surrounded by abrupt changes. Location of wire breakage measured by magnetic characteristic parameters is 300.75 mm, and the error is 0.25% compared with the actual location of wire breakage of 300 mm. Compared two broken wires with one broken wire, the ratio of crest or trough's average depth is 1.82, the ratio of crest or trough's average width is 1.07, the ratio of average area surrounded by the mutation is 1.95. The area surrounded by the mutation is more effective as an evaluation index for the number of broken wires.6 tabs, 14 figs, 27 refs.

References:

[1] 钱 骥,孙利民,蒋 永.桥梁拉索损伤声发射监测研究进展[J].应用声学,2016,35(4):369-376.
QIAN Ji,SUN Li-min,JIANG Yong.Advances in acoustic emission technique to cables health monitoring[J].Journal of Applied Acoustics,2016,35(4):369-376.
[2]XIN H H,CHENG L,DIENDER R,et al.Fracture acoustic emission signals identification of stay cables in bridge engineering application using deep transfer learning and wavelet analysis[J].Advances in Bridge Engineering,2020,1:613.
[3]ZEJLI H,GAILLET L,LAKSIMI A,et al.Detection of the presence of broken wires in cables by acoustic emission inspection[J].Journal of Bridge Engineering,2012,17(6):921-927.
[4]LI S L,WU Y Q,SHI H S.A novel acoustic emission monitoring method of cross-section precise localization of defects and wire breaking of parallel wire bundle[J].Structural Control and Health Monitoring,2019,26(4):e2334.
[5]BIEN J,KAMINSKI T,KUNAWA M.Taxonomy of non-destructive field tests of bridge materials and structures[J].Archives of Civil and Mechanical Engineering,2019,19(4):1353-1367.
[6]POTENZA F,RINALDI C,OTTAVIANO E,et al.A robotics and computer-aided procedure for defect evaluation in bridge inspection[J].Journal of Civil Structural Health Monitoring,2020,10(3):471-484.
[7]PENG P C,WANG C Y.Use of gamma rays in the inspection of steel wire ropes in suspension bridges[J].NDT & E International,2015,75:80-86.
[8]NI Y C,ALAMDARI M M,YE X W,et al.Fast operational modal analysis of a single-tower cable-stayed bridge by a Bayesian method[J].Measurement,2021,174:109048.
[9]YANG Y Q,WANG X,WU Z S,et al.Damping properties of FRP cables for long-span cable-stayed bridges[J].Materials and Structures,2016,49(7):2701-2713.
[10]LARDIES J,MINH-NGI T.Modal parameter identification of stay cables from output-only measurements[J].Mechanical Systems and Signal Processing,2011,25(1):133-150.
[11]SOMAN R,KYRIAKIDES M,ONOUFRIOU T,et al.Numerical evaluation of multi-metric data fusion based structural health monitoring of long span bridge structures[J].Structure and Infrastructure Engineering,2018,14(6):673-684.
[12]SANTOS J P,CREMONA C,ORCESI A D,et al.Early damage detection based on pattern recognition and data fusion[J].Journal of Structural Engineering,2017,143(2):04016162.
[13]郭 健,钟昊荪.基于实测数据的斜拉索振动分析与小波包能量占比研究[J].桥梁建设,2021,51(3):25-31.
GUO Jian,ZHONG Hao-sun.Vibration analysis and wavelet packet energy ratio of stay cable based on measured data[J].Bridge Construction,2021,51(3):25-31.
[14]ZHANG P F.Ultrasonic guided wave approach incorporating SAFE for detecting wire breakage in bridge cable[J].Smart Structures and Systems,2018,22(4):481-493.
[15]ZHANG Y Y,LI D S,ZHOU Z.Time reversal method for guided waves with multimode and multipath on corrosion defect detection in wire[J].Applied Sciences,2017,7(4):424-439.
[16]XU J,WU X J,CHENG C,et al.A magnetic flux leakage and magnetostrictive guided wave hybrid transducer for detecting bridge cables[J].Sensors(Basel,Switzerland),2012,12(1):518-533.
[17]TANG Z F,SUI X D,DUAN Y F,et al.Guided wave-based cable damage detection using wave energy transmission and reflection[J].Structural Control and Health Monitoring,2021,28(5):e2688.
[18]LIU S W,SUN Y H,JIANG X Y,et al.A review of wire rope detection methods,sensors and signal processing techniques[J].Journal of Nondestructive Evaluation,2020,39(4):1-18.
[19]辛荣亚,张启伟.基于漏磁检测的桥梁拉索钢丝损伤评估[J].桥梁建设,2019,49(3):51-56.
XIN Rong-ya,ZHANG Qi-wei.Assessment of steel wire damages in bridge cables based on magnetic flux leakage examination[J].Bridge Construction,2019,49(3):51-56.
[20]ZHANG H,LIAO L,ZHAO R Q,et al.The non-destructive test of steel corrosion in reinforced concrete bridges using a micro-magnetic sensor[J].Sensors(Basel,Switzerland),2016,16(9):1439.
[21]NI Y C,ZHANG Q W,XIN R Y.Magnetic flux detection and identification of bridge cable metal area loss damage[J].Measurement,2021,167:108443.
[22]WANG H Y,TIAN J,LI X W,et al.Inspection of mine wire rope using magnetic aggregation bridge based on magnetic resistance sensor array[J].IEEE Transactions on Instrumentation and Measurement,2020,69(10):7437-7448.
[23]周建庭,杨文琦,夏润川,等.镀锌钢绞线断丝的自发漏磁检测试验[J].江苏大学学报(自然科学版),2019,40(6):713-718,726.
ZHOU Jian-ting,YANG Wen-qi,XIA Run-chuan,et al.Self-magnetic flux leakage test of broken wire of galvanized steel wire[J].Journal of Jiangsu University(Natural Science Edition),2019,40(6):713-718,726.
[24]江胜华,侯建国,何英明,等.基于磁偶极子的磁场梯度张量局部缩并及试验验证[J].中国惯性技术学报,2017,25(4):473-477.
JIANG Sheng-hua,HOU Jian-guo,HE Ying-ming,et al.Theoretical study and experimental verification of magnetic gradient tensor partial contraction using magnetic dipole[J].Journal of Chinese Inertial Technology,2017,25(4):473-477.
[25]江胜华,申 宇,褚玉程.基于磁偶极子的磁场梯度张量缩并的试验验证及相关参数确定[J].中国惯性技术学报,2015,23(1):103-106,114.
JIANG Sheng-hua,SHEN Yu,CHU Yu-cheng.Experimental verification and related parameter's determination for magnetic gradient tensor contraction using magnetic dipole[J].Journal of Chinese Inertial Technology,2015,23(1):103-106,114.
[26]JIANG S H,WANG H,LIU A Z.Rebar corrosion monitoring using magnetic gradient and partial modulus[J].Measurement,2020,164:107994.
[27]江胜华,侯建国,何英明.基于磁场梯度张量局部模量的钢筋锈蚀监测方法[J].西南交通大学学报,2021,56(6):1176-1184.
JIANG Sheng-hua,HOU Jian-guo,HE Ying-ming.Steel corrosion monitoring based on partial modulus of magnetic gradient tensor[J].Journal of Southwest Jiaotong University,2021,56(6):1176-1184.

Memo

Memo:
-
Last Update: 2022-07-20